3) Forming the pipings
1. Wrap the connecting portion of indoor unit with
the Insulation material and secure it with two
Plastic Bands.(for the right piping)
• If you want to connect an additional drain hose, the
end of the drain-outlet should be off the
ground.(Do not dip it into water, and fix it on the
wall to avoid swinging in the wind.)
In case of the Outdoor unit to be installed below
the position of the Indoor unit.
2. Tape the Piping, drain hose and Connecting
Cable from down to up.
3. Form the piping gathered by taping along the
exterior wall and fix it onto the wall by saddle or
equivalent.
In case of the Outdoor unit being installed upper
position of the Indoor unit.
2. Tape the Pipings and Connecting cable from
down to up.
3. Form the pipings gathered by taping along the
exterior wall, make the Trap to be required to
prevent the room from entering the water.
4. Fix the pipings onto the wall by saddle or equiv-
alent.
Seal a small opening
around the pipings
with gum type sealer.
Trap is required to prevent the electrical parts
from entering the water.
-33-
Taping
Drain
hose
Pipings
Plastic Band
Connecting
cable
Seal a small opening
around the pipings
with gum type sealer.
Trap