4. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 0.5°C, the com-
pressor OFF temperature is the setting temperature minus 0.5°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to
the Cooling operation.
• When the room temperature falls the compressor OFF temperature, the operation mode is switched to the
Soft Dry Operation.
• The operation diagram is shown below.
ROOM TEMP.
SETTING TEMP.+0.5 C
(COMP. ON)
SETTING TEMP.
(COMP. OFF)
INDOOR FAN
COMPRESSOR
5. Cooling Mode with Sleep Mode Auto Control
• When selecting the Cooling(
as following.
• The setting temperature will be automatically raised by 1°C 30 minutes later and by 2°C 1 hour later.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP.+0.5 C
(Compressor ON)
SETTING TEMP.-0.5 C
(Compressor OFF)
INDOOR FAN SPEED
COMPRESSOR
Operation
Dry Operation
Cooling
40 seconds
3.2 minutes
Selecting
OFF
LOW
fan speed
ON
OFF
) combined with the Sleep Mode Auto Control(
30 minutes
More than
3 minutes
Low
Low
ON
OFF
10 minutes
3.2 minutes
LOW
ON
1 C
More than
3 minutes
Low
Low
ON
OFF
-14-
40 seconds
maximum
10 minutes
OFF
LOW
LOW
OFF
ON
), the operation diagram is
30 minutes
Low
ON
maximum
3 minutes
1 C