A good note here is that, with the typical LO frequencies as shown in the exam-
ple above, transmit and receive L-band frequencies are widely separated. If the
signals were within the LNB stability/drift frequency limits, there might be a
tendency for the receive side to attempt locking to its own transmit signal.
Considering the L-band IF range is 950 MHz or more spanning close to an
octave, the variation in loss between the high and low ends of the IF range may
be significant.
A nominal design point may be to allow for 10 to 15 dB of total cable loss and
select cable that will reliably achieve this. A more accurate "rule of thumb"
would be to design for a total gain from the antenna to modem receive input of -
40 dBm. For example, if the receive LNB has a gain of 60 dB and there are no
other losses, then the cable can have a maximum loss of 20 dB (60 – 40 dB). In
formula form this is:
Loss (cable max) = Gain (LNB) – 40 – Loss (misc)
Or, for the transmit side, the cable loss should not keep the input to the BUC
from reaching its Power input for 1 dB compression point. Arbitrarily allowing
a 3 dB margin in the modem output, this formula would be:
Loss (cable max) = +3 – BUC Pin (1dB) – Loss (misc)
Notice that this assumes no miscellaneous losses in the transmit or receive side,
but there may be other losses such as from a splitter or output sample port, if
used.
See table 6-1 below for typical cable characteristics (note that cable prices are
estimates only).
RG58 (50Ω)
RG59 (75Ω)
RG6 (75Ω)
RG11 (75Ω)
Times LMR-240 (50Ω)
Times LMR-300 (50Ω)
A p p e n d i x C - D y n a m i c P o w e r C o n t r o l
Table C-3
Cable Type
Max. Freq.
(MHz)
1,000
1,000
2.200
2.200
5,000
5,000
S i g n a l P o w e r L e v e l C o n s i d e r a t i o n s
Typical Coaxial Cable Characteristics
O.D.
Loss/100
(inch)
feet (dB)
@1.2 GHz
0.19
0.25
0.25
0.405
0.24
0.30
in dB
in dB
Shielding
Efficiency
(dB)
21.0
70
18.0
70
10.0
>90
5.0
>90
9.2
>90
6.8
>90
Estimated
Cost/ft.
(USD)
0.39
0.39
0.89
0.89
0.47
0.53
C-17