Models 95L, 95LWEZ, and 95LE Summit Trainers
LED Diagnostics
TEST/SERVICE – MISCELLANEOUS TEST 1
The field duty cycle being applied to the alternator is displayed in the heart rate window.
This value ranges from 0 to 255. The alternator output voltage is displayed in the distance
window. The alternator RPM is displayed in the RPM window.
The load duty cycle applied to the alternator will be displayed in the calories window. The
value ranges from 0 to 250 and can be adjusted using the TIME UP and TIME DOWN arrow
keys.
Pressing the AEROBICS MODE key will toggle the speaker on and off.
Pressing the "0" key will toggle the RPM display between the alternator RPM and the reed
switch RPM. The ENTER key LED will be on when the alternator RPM is displayed. Reed
switch will not be displayed when the alternator is running.
Pressing the "5" key will toggle the alternator on and off.
Press ENTER to advance to the next diagnostic state. Press CLEAR to return to the previous
state. Press CLEAR repeatedly to exit diagnostics.