Domestic Compact Electrical Systems
2.11. The key switch has four spade terminals.
See Figure 2.11.
Figure 2.11
•
The red wires with white trace (terminal A & B)
are fused constant hot-leads.
•
In the OFF position, no terminals are connected.
•
In the RUN position, only terminals B and C are
connected to, sending power through the red
wire with black trace to the lighting and acces-
sory circuits and pin # 18 (run input) on the
instrument panel.
•
The START position makes the "RUN" con-
tacts, and A terminal and D terminal are con-
nected to each other, sending power through the
orange wire to pin #16 (start input) on the panel.
2.12. The instrument panel is easily unplugged or
removed with the hood open. See Figure 2.12.
Molded connector
Mounting Bolts
Figure 2.12
K&T Saw Shop 606-678-9623 or 606-561-4983
www.mymowerparts.com
2.13. The pin numbers are indicated on the molded
back row: # 16 -> # 23
center row: # 9 -> # 15
near row:
"23"
"8"
2.14. Each number corresponds to a pin position on
Pins on instrument
panel connection
86
connector. See Figure 2.13.
# 1 -> # 8
Figure 2.13
the instrument panel. See Figure 2.13.
Figure 2.14
"16"
"1"