Initialization Of D, C; Initializing The D Page Data; Modification Of D; D Page Table - Sony DCR-TRV5 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV5:
Table of Contents

Advertisement

3-2. INITIALIZATION OF D, C PAGE DATA

1. Initializing the D Page Data

Note: If the page D data is initialized, the following adjustments must be
performed again.
1) Modification of D page data
2) Clock adjustments of the video system adjustments
3) Base band block adjustments of the video system adjustments
4) Zoom Key Center Adjustment of the camera system adjustments
5) Color electronic viewfinder system adjustments
6) LCD system adjustments
7) IR transmitter adjustments
8) Battery end adjustment
Adjusting page
D
Adjusting Address
00 to FF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 00, and set data: 2D, and press the
PAUSE button of the adjustment remote commander.
3) Select page: 2, address: 01, set data: 2D, and press the PAUSE
button.
4) Select page: 2, address: 02, and check that the data is "01".
5) Perform "Modification of D Page Data".
2. Modification of D Page Data
If the D Page data has been initialized, change the data of the "Fixed
data-2" address shown in the following tables by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder
may not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5) After changing the data, select page: 0, address: 01, and set
data: 00.

3. D Page Table

Note: Fixed data-1 : Initialized data. ( Refer to "1. Initializing the D Page
Data".)
Fixed data-2 : Modified data. (Refer to "2. Modification of D PAGE
Data").
Initial value
Address
NTSC
PAL
00 to 0F
10
00
00
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
70
70
29
77
77
2A
A0
A0
2B
AD
AD
2C
C0
C0
2D
2E
2F
30
31
32
33
34
35
36
37
70
70
38
39
3A
3B
3C
3D
3E
3F
5-34
Remark
Test mode
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Battery end adj.
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Battery end adj.
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv5eRmt-808Rmt-809

Table of Contents