Initialization Of 4, 8, 9, A, B, C, D, E, F; 1E, 1F Page Data; Modification Of A, D Page Data - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

DCR-IP210/IP210E/IP220/IP220E
COVER
COVER
1-2.

INITIALIZATION OF 4, 8, 9, A, B, C, D, E, F,

1B, 1E, 1F PAGE DATA
Note: When reading or writing the 1B, 1E or 1F page data, select page: 0,
address: 10, and set data: 01, then select B, E or F page. The 1B, 1E
or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
1-2-1. INITIALIZATION OF A, D PAGE DATA
Note: The data of page: 0, address: 10 must be "00"
1. Initializing the A, D Page Data
Note1: If "Initializing the A, D Page Data" is performed, all data of the A
page and D page will be initialized. (It is impossible to initialize a
single page.)
Note2: If the A, D page data has been initialized, the following adjustments
need to be performed again.

1) Modification of A, D page data

Note3: NTSC model: DCR-IP210/IP220
PAL model: DCR- IP210E/IP220E
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method:
Order Page Address Data
1
0
01
2
0
10
3
7
03
4
7
00
5
7
01
6
7
02
7
2
00
8
2
01
9
A
10 to FF
D
10 to 6C
Procedure
01
Set the data.
00
Set the data.
Set the following data.
01 (NTSC), 81 (PAL)
28
Set the data.
28
Set the data, and press PAUSE
button.
Check that the data changes to
"01"
29
Set the data.
29
Set the data, and press PAUSE
button.
Perform "Modification of A, D
Page Data".
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
"Fixed data-2" address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, D Page data
Order Page Address Data
1
2
00
2
2
01
Note: If the following symptoms occur after completing of the
"Modification of A, D page data", check that the data of the "Fixed
data-2" addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code "E:20:00" on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
6-10
Procedure
29
Set the data.
29
Set the data, and press PAUSE
button.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-ip210eDcr-ip220Dcr-ip220e

Table of Contents