OSD ROTATION: Sets the OSD display direction.
AUTO: The OSD rotates automatically when the monitor is rotated. OSD ROTATION
is set to AUTO by default.
LANDSCAPE: The OSD appears in landscape orientation.
PORTRAIT: The OSD appears in portrait orientation.
MAIN IMAGE ROTATION: Sets the main image display direction.
AUTO: The image automatically rotates according to the orientation of the monitor.
IMAGE ROTATION is set to AUTO by default.
LANDSCAPE: The image is not rotated.
PORTRAIT: The image is rotated.
SUB IMAGE ROTATION: Sets the sub image display direction.
AUTO: The image automatically rotates according to the orientation of the monitor.
IMAGE ROTATION is set to AUTO by default.
LANDSCAPE: The image is not rotated.
PORTRAIT: The image is rotated.
This function changes the display image to monochrome.
There are 4 types of settings.
OFF: The Display Image is COLOR.
MODE1: The signal Input is 8 bit monochrome. The display shows a grayscale image.
This mode uses only the Green channel of an R/G/B input signal.
MODE2: Input is R/G/B Color, but the monitor changes the color space to YUV. The
displayed image will become monochrome. Only Y data passes the R/G/B LUT.
10BIT: The signal Input is 10 bit monochrome. The display shows a grayscale image.
This mode is used in conjunction with specifi c display controllers.
Provides a quick daily visual image quality check of this diagnostic monitor by just using
a button on the monitor. See page 15.
,
*
1
Video Band Width: Reduce the visual "noise" level of the input signal. It is strong
ineffective, so that a number becomes small. Press "LEFT" or "RIGHT" to select.
Sync Threshold: Adjusts the slice level of a synchronization signal. Press "SELECT" to
move the adjustment menu. Adjusts the sensitivity of the separate or composite input
signals.
Try this option if the FINE adjustment does not successfully eliminate the noise.
Clamp position: Operating your monitor at a non-standard timing may cause images to
appear darker than normal or have color distortion. Use of the Clamp position control will
adjust images to their normal state.
Selects the Calibration mode (page 30).
1
1
Displays an all white screen.
1
Current internal temperature is shown in degrees (C).
The estimated remaining lifetime of the display backlight is indicated here. Backlight
lifetime depends mainly on the desired calibrated settings. The lower the calibrated
setting, the longer the backlight's estimated lifetime.
1
Shows total running time.
1
Shows the lux value calculated by the ambient light sensor. The ILLUMINANCE value is
dependent on the type and position of light source. It may differ from the value measured
by the illuminance meter.
1
Provides information about the current display resolution. Technical data, including the preset
timing currently being used and the horizontal and vertical frequencies is also displayed.