Electrical Information; Recommendation For Wire - Heat & Glo Cyclone-Cust Owner's Manual

Installation and operation
Table of Contents

Advertisement

10
10

Electrical Information

A. Recommendation for Wire
This appliance requires 110-120 VAC be wired directly to
the transformer. See Figure 10.1.
1. Ensure that the electrical service being installed to
the appliance is turned "OFF" by verifying with a volt
meter.
WARNING
Shock hazard.
Wire 110V to transformer.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override HSI safety lockout
and may cause explosion.
2. Bring the electrical service wire through the wire re-
straint located on the right side of the appliance. Leave
about 10 inches of electric service wire inside the ap-
pliance to permit for future service maintenance.
3. Locate the (2) female insulated connectors installed on
the transformer and the (1) ground connector screwed
to the right side of the transformer bracket.
Note: The factory installed yellow female insulated connectors
(2) and yellow ground connector (1) are designed for use with
10/12 AWG wire. If another gauge wire is being used, these
connectors should be replaced with the appropriate gauge
insulated connectors to ensure a proper connection. See
Figure 10.2.
4. Route electrical service wires through plastic grom-
met as show in Figure 10.1. This plastic grommet is
located on the right side of the Transformer bracket.
5. Connect the L1 (Black) service wire to the supplied
yellow female insulated connector located on trans-
former terminal (23) using a wire crimping tool. See
Figure 10.2.
*Front of fi replace has been removed to show the electrical panel position within appliance.
*Front of fi replace has been removed to show the electrical panel position within appliance.
Figure 10.1 Electrical Panel position inside Appliance with Front removed.
28
Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08
6. Connect the neutral (White) service wire to the yellow
female insulated connector located on transformer ter-
minal (1) using a wire crimping tool. See Figure 10.2.
7. Connect the ground (Green) wire to the 1/4 in. ground
screw located on the front right of the transformer
bracket. See Figure 10.2.
Connectors
Connectors
Transformer bracket
Transformer bracket
Figure 10.2
Note: The system is polarity sensitive. Polarity must be
correct for this fi replace to operate correctly.
Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
Plastic grommet
Plastic grommet

Advertisement

Table of Contents
loading

Table of Contents