Securing the Vent Sections
Vertical Sections
Vertical sections of pipe must be supported every 8 feet
above the fi replace base. For the Cyclone, there must be
an additional vent support (wall bracket) placed around the
fi rst section of pipe (see Figure 8.9). The vent support or
plumber's strap (spaced 120º apart) may be used.
Horizontal Sections
Horizontal sections of vent must be supported every 5 feet
with a vent support or plumber's strap.
DO NOT SEAL
OR SCREW
1 IN.
MINIMUM
*Note: This fi rst section of pipe must be secured to the framing to make it
rigid and allow it to support the remaining pipe sections.
Figure 8.9 Installing Support Brackets
Figure 8.10 Securing Horizontal Pipe Sections
22
WALL
BRACKET
WALL
STUD
8 FT.
(2.4mm)
*WALL
3 in. Min.
BRACKET
SLIP SECTION
(CYCLONE-12 SLIP)
GLASS TUBE
FIREPLACE
BASE
Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08
B. Disassembly of Vent Sections
To disassemble any two pieces of pipe, rotate either section
(see Figure 8.11), so that the seams on both pipe sections
are aligned (see Figure 8.12). They can then be carefully
pulled apart.
WARNING
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation
instructions.
Connect vent sections per installation
instructions.
• Maintain all clearances to combustibles.
• Do NOT allow vent to sag below
connection point to appliance.
Improper support may allow vent to sag or separate.
Figure 8.11 Rotate Seams for Disassembly
Figure 8.12 Align and Disassemble Vent Sections