Ê Close the processor holder (2).
Ê Lock the processor in the socket by returning the spring clip to its original
position (3).
Ê Apply a small amount of thermal paste to the upper side of the new
processor.
Ê Ensure a thin and even distribution of the thermal paste.
Ê Place the heat sink on the processor (see
Ê Fasten the heat sink by tightening the four screws in a crossover pattern.
Ê Reinstall the air duct as described in the
Ê Close the server, connect it to the power outlet, and switch it on as described
in the
chapter "Completion" on page
RX200 S6
figure 10 on page
chapter "Completion" on page
73.
Options Guide
Processors
38).
73.
41