Electrolux W365H Service Manual page 238

Clarus control
Hide thumbs Also See for W365H:
Table of Contents

Advertisement

50
Error message on display:
Failed. Press SELECT.
Possible causes:
Calibration switch incorrectly set. An incorrect calibration weight has been
used for calibration.
Fault-finding procedure:
• If you are or have recently been calibrating the weighing equipment, the
Fig.
calibration switch may be incorrectly set, or an incorrect calibration
4
weight may have been used for calibration.
Check that the calibration switch is set correctly. It should normally be
set to NORM. During calibration the switch should be set to CAL.
If relevant/necessary, calibrate the weighing equipment, or follow the
"Calibrate the scale" procedure under "Machine operation".
• Check that all cables/wiring to the scale unit are sound and correctly
connected.
4
Calibration switch
8
50. Weighing equipment
Connections, load
cells
Service
Manual
Connector, power
supply
Connector, CPU
communication
5955
438 9073-61/01
04.03