Networking Parameters - 3Com V6100 User Manual Manual

Sip gateway
Hide thumbs Also See for V6100:
Table of Contents

Advertisement

Figure 85
SIP ini File Example
PCMLawSelect = 1
ProtocolType = 1
TerminationSide = 0
FramingMethod = 0
LineCode = 2
TDMBusClockSource = 4
ClockMaster = 0
;Channel Params
DJBufMinDelay = 75
RTPRedundancyDepth = 1
IsProxyUsed = 1
ProxyIP = 192.168.122.179
CoderName = g7231,90
;List of serial B-channel numbers
TrunkGroup_1 = 0/1-24,1000
TrunkGroup_2 = 1/1-24,2000
TrunkGroup_3 = 2/1-24,3000
TrunkGroup_4 = 3/1-24,4000
EnableSyslog = 1
SyslogServerIP = 10.2.2.1
CallProgressTonesFilename = 'CPUSA.dat'
;CASFileName = 'E_M_WinkTable.dat'
SaveConfiguration = 1

Networking Parameters

Table 42
Networking Parameters
ini File Field Name
Web Parameter Name
EthernetPhyConfiguration
156
Valid Range and Description
0 = 10 Base-T half-duplex
1 = 10 Base-T full-duplex
2 = 100 Base-TX half-duplex
3 = 100 Base-TX full-duplex
4 = auto-negotiate (default)
For detailed information on Ethernet interface configuration,
see
Ethernet Interface
Configuration.
V6100 and V7122 User Guide

Advertisement