5.4 Modifiable parameters  
This table lists the model choice or cycle and temperature option parameters. 
F/M 
ID 
Description 
P0 
Appliance Type 
P1 
Appliance Model 
P2 
Boiler temperature 
P3 
Tank temperature 
P4 
Thermostop option 
P5 
Soft Start option 
P6 
Boiler temperature 
offset 
P7 
Tank temperature 
offset 
P8 
Real temperature 
display 
P9 
Tank probe type 
 
Note for P6 and P7: negative numbers are indicated by illumination of both decimal points (e.g.:  ‐12 
"1.2.") 
 
5.5 Alarm trigger time thresholds  
This table lists all the safety device trigger time thresholds. 
F/M 
ID 
Description 
A0 
 
A1 
Boiler max. heating time 
A2 
Tank max. heating time 
A3 
Maximum water intake time 
A4 
Maximum emptying wait time 
 
 
CW/CWH – 511 MDA 
Default 
Notes 
05 
Construction version 
Do not modify 
05 
Do not modify 
80 
Step 1 degree 
WARNING: The actual boiler temperature 
depends on whether the connection is single‐
phase or three‐phase. 
With three‐phase connection, do not set more 
than 85° 
58  
Step 1 degree 
01 
0=off 1=on 
01 
0=off 1=on Do not modify 
00 
Real=measured + Offset 
04 
Real=measured + Offset 
01 
0= filtered, 1= real 
01 
Do not modify 
Default 
 
20 min 
60 min 
5 min 
1 min 
15 
Min 
Max
Notes 
 
 
 
60 
Step = 1 min  
60 
Not active with PL ON 
20 
Step = 1 min 
Step = 1 min 
 