5.7 Adjusting the regeneration frequency (models with softener only) 
Memorisation procedure   
 
To access the programming menu, proceed as follows:  
1) switch the appliance off by pressing the On Off 
2) Hold down the 
3) Use the  
  key to modify the parameter; H0,H1,H2,H3,H4,H5 and H0 will appear on the display 
in cyclic sequence 
4) Press the On Off key to confirm the change and quit programming mode. 
 
 
With  values  over  60°dF  an  external  water  treatment  device  must  be  used  and  the 
regeneration frequency must be set at H00 
 
 
5.8 Table of parameters  
This table shows the relationship between the intake water hardness and the quantity the resins are 
able to treat; regeneration is required once the appliance has performed the set number of cycles. 
Regeneration cycle duration: 12 minutes. 
 
Hardness (°dH German 
degrees) 
 Regeneration off 
8.5 
11 
17 
22,5 
28 
33.5 
 
 
 
 
 
 
 
CW/CWH – 511 MDA 
  and 
 keys simultaneously for 6 seconds; H0 appears on the display 
Hardness (°dF French 
degrees) 
Regeneration off 
15 
20 
30 
40 
50 
60 
key
 
Setting level 
H00 
H01 
H02 
H03 
H04 
H05 
H06 
17 
Resin duration in 
wash cycles 
Function off 
94 wash cycles 
83 wash cycles 
53 wash cycles 
33 wash cycles 
27 wash cycles 
20 wash cycles 