Venting Fireplace - Rear (Nat Models Only) - Empire Comfort Systems DVP36DP31N-2 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36DP31N-2:
Table of Contents

Advertisement

vENTING FIREpLACE - REAR (NAT GAS MODELS ONLY)
To Use the vent Graph (Figure 39)
1. Determine the height of the center of the horizontal
vent pipe. Using this dimension on the Sidewall
Vent Graph, locate the point it intersects with the
slanted graph line.
2. From the point of this intersection, draw a vertical
line to the bottom of the graph.
3. Select the indicated dimension, and position the
unit in accordance with same.
EXAMpLE A:
If the vertical dimension from the floor of the unit is
12 feet, 4 inches the horizontal run to the outer wall
flange must not exceed 12 feet, 3 inches.
EXAMpLE B:
If the vertical dimension from the floor of the unit is
6 feet, 9 inches, the horizontal run to the outer wall
flange must not exceed 6 feet, 6 inches.
SpECIAL NOTICE: For each 45 degree elbow
installed in the horizontal run, the length of the
horizontal run MUST be reduced by 18" (45cm). This
does not apply if the 45 degree elbows are installed
on the vertical part of the vent system. Reduce 3'
for every 90° elbow.
Example: According to the chart the maximum
horizontal vent length is 20' and if two 45 degree
elbows are required in the horizontal vent it must
be reduced to 17'.
The maximum number of 45 degree elbows permitted
per side wall installation is two (2). These elbows can
be installed in either the vertical or horizontal run.
NOTICE: Only natural gas models can be rear
vented.
Page 28
venting Graph (Dimensions in Feet)
REAR EXIT - VERTICAL AND HORIZONTAL TERMINATION
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
REAR HORIZONTAL
VENT CONNECTION
Acceptable vertical and horizontal vent run.
Unacceptable vertical and horizontal vent run.
(DIMENSIONS IN FEET)
A
B
HORIZONTAL RUN
Figure 39
26927-8-0611