Instructions for the installer

13.INSTALLING THE APPLIANCE

It is the law that all gas appliances are installed by competent persons.
This appliance may be installed next to a wall which is higher than the appliance, with a minimum
distance of 5 cm from the side of the appliance, as shown in drawings A and B showing the correct
installation conditions. Any wall cupboards or shelves must be at a distance of at least 75 cm above the
work surface.
A)
B)
Built-in appliance
Free-standing appliance

13.1 Electrical connection

Make sure the voltage and the cross-section of the power cord match the specifications indicated on the
rating plated positioned in the storage compartment. Do not remove this plate for any reason.
If the appliance is connected to the power grid using a fixed connection, fit the power line with an
omnipolar circuit-breaker, in accordance with the installation instructions, located in a readily accessible
position near the appliance.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket
must be suitable for the cable employed and conform with the regulations in force. Regardless of the
type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that
the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.
For operation on 220-240V~: use an H05V2V2-F type three-core
220-240V~
2
2.5 mm
2
cable (3 x 2.5 mm
).
The earth wire (yellow-green) must be at least 20 mm longer than
20 mm
the other wires at the end for connection to the appliance.
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions.
16