Equipment Troubleshooting; Please Read The Following Carefully - Chicago Electric 65309 Set Up, Operating, And Servicing Instructions

15,000 w, 540 rpm pto generator
Table of Contents

Advertisement

Problem
No output or low
output
Output voltage is too
high.
Generator is
overheating.
Sparking at brushes.
Follow all safety precautions whenever diagnosing or servicing the
equipment or generator.

PLeaSe Read The FOLLOWinG caReFuLLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS qUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
qUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/
OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD
BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE
BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE
ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER
INSTALLATION OF REPLACEMENT PARTS THERETO.
SKU 65309
For technical questions, please call 1-800-444-3353.

equipment Troubleshooting

Possible causes
1.
Open or shorted rotor.
2.
Open or shorted stator.
3.
Generator operating below correct
speed.
4.
Generator overloaded.
5.
Short circuit in load.
1.
Incorrect Adjustable Voltage
Regulator (AVR) setting.
2.
Engine speed is too high.
1.
Generator is overloaded.
2.
Rotor is rubbing stator.
3.
Poor ventilation.
4.
Short circuit in stator.
5.
Shorted turns in rotor.
1.
Generator is overloaded.
2.
Brushes not seated properly.
3.
Brushes sticking in holder.
4.
Brushes worn to less than 3/8".
Probable Solutions
1.
Replace rotor.
2.
Replace stator.
3.
Operate generator at correct
speed.
4.
Reduce load to rated output.
5.
Disconnect load. Check voltage at
all receptacles. Repair short.
1.
Readjust Adjustable Voltage
Regulator (AVR) setting.
2.
Reduce engine speed.
1.
Reduce load.
2.
Check bearings (23 and 27). Repair
or replace as needed.
3.
Ensure generator air vents are
clear.
4.
Check stator, repair or replace as
needed.
5.
Repair or replace rotor.
1.
Reduce load.
2.
Contour and re-seat brushes.
3.
Remove brushes, clean holder and
reinstall brushes.
4.
Replace brushes. NOTE: Replace
brushes in pairs.