Control Panel Features - Chicago Electric 65309 Set Up, Operating, And Servicing Instructions

15,000 w, 540 rpm pto generator
Table of Contents

Advertisement

cOnTROL PaneL FeaTuReS

1.
20 amp circuit breakers.
cuit breaker protects a 125 V~ outlet
against short or overload. These are
"push to reset" type.
2.
30 amp circuit breaker.
the 30 Amp 125 V~ outlet against
short or overload. This is "push to
reset" type.
3.
duplex 125 v~ GFci Receptacles.
Use these for 125 V~, 60 Hz, single
phase loads up to 20 A (combined
per duplex outlet).
4.
Single 125 v~ Receptacle.
for 125 V~, 60 Hz, single phase de-
vices up to 30 A.
Single 125/250 v~ Receptacle and
5.
circuit breakers. Use a 4-blade
grounded connector to operate
125/250 V~, 60 Hz, single phase
SKU 65309
For technical questions, please call 1-800-444-3353.
Each cir-
Protects
6.
7.
8.
Use this
9.
10.
loads requiring up to 50 Amps of
current up to 12,000 Watts (12kW) of
power. Use a connector rated to 250
Volts, 50 Amps with a same-rated
4-wire set. The 50 Amp circuit break-
ers protect each hot line of the circuit.
Single 12v dc receptacle.
power 12VDC loads at 8.3 Amps.
volt / Frequency / Time digital Me-
ter. Used to monitor the AC voltage,
frequency and operating speed.
Grounding Terminal.
AWG copper wire or larger to connect
to an earth-driven copper or brass
grounding rod.
amp circuit breaker.
8.3 Amp 12 DC outlet against short or
overload. This is "push to reset" type.
voltage Switch.
240V on the left,
120V on the right.
Used to
Connect to #6
Protects the
REV 09d
Page 7