Section 3: Appliance Location & Clearances A. Selecting Appliance Location; Clearances To Combustibles - Quadra-Fire SAPPHIRE-MBK Owner's Manual

Sapphire series gas stove direct vent room heater
Hide thumbs Also See for Quadra-Fire SAPPHIRE-MBK:
Table of Contents

Advertisement

3
Appliance Location and Clearances
NOTE:
·
Illustrations refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
·
Illustrations/diagrams are not drawn to scale.
·
Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see Figure 3.1).
NOTE: For actual appliance dimensions refer to
Section 12.
B. Clearances to Combustibles
F
B
A
Sapphire Gas Stove
Figure 3.1
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
D
E
A
Model
Inches
Millimeters
Quadra-Fire • Sapphire • 7055-116 Rev. G • 10/12
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffi c areas.
Fire Risk.
Locate and install appliance to all
clearance specifi cations in manual.
C
C
A
B
C
D
6
6
3
54
152
152
76
1372
Fire Risk.
Odor Risk.
Tipping Risk
Install appliance on a stable, level platform/
fl oor strong enough to support appliance
without tipping.
USE wood fl ooring, ceramic tile, brick hearth
or high pressure laminate fl ooring applied
directly over the sub-fl ooring material.
WARNING
WARNING
A
E
F
36
34
914
1016
WARNING
A
7

Hide quick links:

Advertisement

Table of Contents
loading