6
Turn misfeed-clearing dial 1 clock-
wise until the removal indicator is
completely blue.
What should be done if misfeed-
?
clearing dial 1 is turned too far?
% Turn misfeed-clearing dial 1
counterclockwise to adjust it so
the cartridge removal indicators
are aligned.
7
Remove all paper fed into the exit
tray 1.
8
Open the Right-side door, and then
pull out any misfed paper in the
transport section.
9
Clockwise turn the misfeed-clearing
dial in the folding section. Feed out
into the exit tray 2 the paper that
could not be fed out in step 8, and
then pull out the paper.
8-32
Troubleshooting
-
Misfeed
clearing
dial 1
Misfeed-
clearing dial
in the folding
section
Removal
indicator
C450P