ELECTRICAL REQUIREMENTS
NOTE:
Wiring
diagram
is located
inside the control console.
Export
models
(not U.S. or Canada):
See Additional
Instructions for Export Models on the other side of this sheet.
I_I,WARNING] WARNING
- To prevent
unnecessary
risk of fire, electrical
shock
or personal
injury, all
wiring
and grounding
must
be done
in accordance
with
local
codes,
or in the
_
bsence
of local
codes,
with the National
Electrical
Code, ANSI/NFPA
(for the United
States)
or the Canadian
Electrical
Code
CSA C22.1 (for Canada).
GROUNDING
This dryer must be grounded.
In the event of malfunction
or breakdown,
the ground will reduce the risk of
electrical
shock
by providing
a path of least resistance
for electrical
current.
GAS
MODELS
This appliance
is equipped
with a cord having
an
equipment-grounding
conductor
and a grounding
plug.
The plug must be plugged
into an appropriate
outlet
that is properly
installed
and grounded
in accordance
with all local codes and ordinances.
Do not modify the plug provided
with the appliance
- if
it will not fit the outlet, have a proper outlet installed
by
a qualified
electrician.
_'WARNING
WARNING - Improper connection of
the equipment grounding conductor can
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if you are in doubt as to whether the
appliance is properly grounded.
if a separate
ground
is required
by local codes,
a grounding
kit (Part No. 12001875)
is available.
It contains
ground
wire, clamp,
ground screw
and washer.
Connect
ground
wire to back of unit with the cabinet
ground
screw and washer.
Secure
other end of ground
wire to a suitable
external
ground
connection.
The wire may
be secured
with the clamp to a grounded
COLD
metal water pipe.
terminal
block post to the frame of the dryer.
If local codes prohibit the use of the
ground strap, the dryer must be grounded
in accordance
with local codes.
If a power cord is not used and the electric dryer is to be permanently
wired,
the dryer must be connected
to a grounded
metal, permanent
wiring system;
or an equipment
grounding
conductor
must be run with the circuit conductors
and connected
to the equipment
grounding
terminal.
NEVER
CONNECT
GROUND
WIRE TO PLASTIC
PLUMBING
LINES,
GAS LINES OR HOT WATER
PIPES.
ELECTRIC
MODELS
1_
U.S. electric
models are shipped
with a ground strap connected
from the neutral
ELECTRICAL
CONNECTIONS
Ground
Screw
BEFORE
OPERATING
OR TESTING,
follow
all grounding
instructions
in Grounding
Section.
An individual
branch
(or separate)
circuit serving
only this appliance
is recommended.
DO NOT USE AN
EXTENSION
CORD.
GAS MODELS - U.S. and Canada
A 120 volt, 60 Hz AC, approved
electrical
service, with a 15 ampere fuse or circuit breaker is required.
ELECTRIC
MODELS
-
U.S. Only
Most U.S. dryers, as manufactured,
require a 120/240 volt, 60 Hz AC approved
electrical
service.
Some require
120/208 volt, 60 Hz approved
electrical
service.
The electric service
requirements
can be found on the data
label located on the front behind the door.
A 30 ampere fuse or circuit breaker on both sides of the line is
required.
Page 5