LOCATION CONSIDERATIONS
The dryer should
be located to permit adequate
room in front for loading the dryer, and sufficient
room behind
the dryer for the exhaust
system.
This dryer is factory-ready
for rear exhaust.
To exhaust
out the bottom
or left side, use the accessory
exhaust
kit (see Accessories).
Instructions
are included
with the kit.
It is important to make sure the room has adequate
make-up air. The area where the dryer is located must not
obstruct the flow of combustion
or ventilating
air.
On gas dryers, adequate
clearance
as noted on the data plate must be maintained
to insure adequate
air for
combustion
and proper operation
of the dryer.
THE DRYER
MUST
NOT BE INSTALLED
OR STORED
IN AN AREA WHERE
IT WILL BE EXPOSED
TO
WATER AND/OR
WEATHER.
THE DRYER AREA
IS TO BE KEPT CLEAR AND FREE FROM
COMBUSTIBLE
MATERIALS,
GASOLINE
AND OTHER
FLAMMABLE
VAPORS
AND LIQUIDS.
A DRYER
PRODUCES
COMBUSTIBLE
LINT.
THE AREAAROUND
THE DRYER
SHOULD
BE KEPT FREE OF LINT.
ALCOVE OR CLOSET INSTALLATION
An appliance
installed
in a closet shall
have no other fuel-burning
appliance
installed
in the same closet.
Each opening
area in the door must
have a minimum
of 36 square
inches.
These openings
must not be obstruct-
ed.
(Louvered
door with equivalent
air
opening
is acceptable.)
FRONT
VIEW
CLOSET
DOOR
i(7.6 cm)
(91.4cm)
36 '+
_
2" (5.1 crn)
_ ................................. (91.4 cm)
3"
(7.6 cm)
SIDE VIEW
_I,WARNING
WARNING-
The dryer must
be exhausted
to
the outside to
reduce the risk
of fire when
installed in an alcove or closet.
Minimum
installation
clearances.
If possible,
more clearance
is recommended.
MOBILE
HOME
INSTALLATION
The installation
of the dryer in mobile homes must conform to the Manufactured
Home Construction
and Safety
Standard
Title 24 CFR, Part 32-80 {formerly the Federal standard for Mobile Home Construction
and Safety, Title
24, HUD (Part 280), 1975} for the United States,) or CSA Standards
Z240 (for Canada).
When installing
a dryer in a mobile home, prowsions
for anchoring
the dryer to the floor must be made.
An
anchor
bracket
kit is available
with instructions
(see Accessories).
Locate in an area that has adequate
make
up air. A minimum
of 25 square
inches (63.5 cm) of unobstructed
opening
is required.
All mobile
home installations
must be exhausted
to the outside
with the exhaust
duct termination
securely
fastened
to the mobile
home structure,
using materials
that will not support
combustion.
The exhaust
duct
may not terminate
beneath
the mobile
home.
See the section
on exhausting
for more information.
EXHAUSTING
Exhausting
the dryer to the outside will prevent large amounts
of lint and moisture from being blown into the room.
In the United
States:
• all gas dryers must be exhausted
to the outside.
° electric
dryers
located
in a confined
area such as a bedroom,
bathroom,
or closet must be exhaust-
ed to the outside.
° electric
dryers
not located
in a confined
area may be exhausted
to the inside (see nonexhausted
installations).
In Canada:
° all gas and electric
dryers
must be exhausted
to the outside.
Outside
the U.S. and Canada:
• refer to local codes.