Important Installation Information
GAS Type Verification
Verify the type of gas supplied to the location. Ensure that
the appliance is connected to the type of gas for which it is
certified. All models are certified for use with natural gas.
Field conversion of the appliance for use with propane gas
supply will require a conversion kit.
WARNING:
To avoid possible burn or fire hazard, a
backguard designed specifically for this range
must be installed whenever the range is used.
Refer to "Chart C: Backguard Kit Model Numbers" on
page 18, for the correct backguard models that are
designed for this range. After selecting the correct
backguard, the range must be installed properly, using the
minimum clearances to combustible surfaces specified in
"Step 2: Cabinet Preparation" on page 4.
Important:
A backguard must be utilized when there is less than a
12" horizontal clearance between combustible
materials and the back edge of the range. A
Thermador backguard must be ordered separately and
installed at the rear of the range. (A Low Back is
supplied with the 30" model.) For island installations
and other installations with more than 12" clearance,
an optional stainless steel Island Trim is available to
cover the backguard mounting flanges.
Verify that the appliance is correct for the type of gas
being provided. Refer to "Step 5: Gas Requirements
and Hookup" on page 11 before proceeding with the
installation.
Gas Supply:
Natural Gas - 6 inch water column. (14.9 mb) min., 14 inch
(34.9 mb) maximum
Propane Gas - 11 inch water column. (27.4 mb) min.,
14 inch (34.9 mb) maximum
Electric Power Supply:
See page 13 for specifications.
This appliance has been tested in accordance with ANSI
Z21.1, Standard for Household Cooking Appliances (USA)
and in accordance with CAN 1.1-M81 Domestic Gas
Ranges (Canadian).
It is stronqlv recommended that this appliance be installed
in conjunction with a suitable overhead vent hood. (See
"Step 1: Ventilation Requirements" on page 3.) Due to the
high heat capability of this unit, particular attention should
be paid to the hood and duct work installation to assure it
meets local building codes.
Check local building codes for the proper method of
appliance installation. Local codes vary. Installation,
electrical connections and grounding must comply with all
applicable codes. In the absence of local codes the
appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223. I/NFPA 54 current
issue and National Electrical Code ANSI/NFPA 70-current
issue. In Canada, installation must be in accordance with
the CAN 1-B149.1 and .2 - Installation Codes for Gas
Burning Appliances and/or local codes.
This appliance complies with one or more of the following
standards:
UL 858, Standard for the Safety of Household Electric
Ranges
UL 923, Standard for the Safety of Microwave Cooking
Appliances
UL 507, Standard for the Safety of Electric Fans
ANSI Z21.1, American National Standard for
Household Cooking Gas Appliances
CAN/CSA-C22.2
No. 113-08 Fans and Ventilators
CAN/CSA-C22.2
No. 61-08 Household Cooking
Ranges
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
Due to the high heat of the cooktop burners, installing a
microwave oven with a ventilation system over the cooktop
is not recommended.