Download Print this page

Step 1: Ventilation Requirements - Thermador PRO-GRAND PD304 Installation Instructions Manual

Professional pro-grand dual fuel ranges
Hide thumbs Also See for PRO-GRAND PD304:

Advertisement

Available languages

Available languages

Step 1: Ventilation Requirements
It is strongly
recommended
that a
suitable exhaust hood be installed
above
the
range.
Downdraft
ventilation
should not be used. The
table
below
indicates
the
Thermador
hoods,
by
model
number,
that are recommended
for use with all ranges.
1. Select Hood and
Blower
Models:
Forwall
installations,
the hood
width
must,
at a minimum,
equal the width of the range
cooking
surface.
Where
space permits,
a hood larger
in width than the cooking
sur-
face may be desirable
for im-
proved
ventilation
perfor-
mance.
For
island
installations,
the
hood width should,
at a mini-
mum,
overhang
the
range
cooking surface by 3" on each
side.
IMPORTANT:
2. Hood
Placement:
Ventilation
hoods and blowers are
designed
for use with single
wall
ducting.
However,
some
local
building
codes or inspectors
may
require double wall ducting.
Con-
sult local
building
codes
and/or
local agencies,
before starting,
to
assure that hood and duct instal-
lation will meet local requirements.
Hood
blower
speeds
should
be variable
to reduce
noise
and loss of heated or air con-
ditioned
household
air when
maximum
ventilation
is not
required.
Normally,
the maxi-
mum
blower
speed
is only
required when using the grill.
For best smoke elimination,
the
lower edge of the hood should
be installed a minimum
of 30" to
a maximum
of 36" above
the
range
cooking
surface.
(See
Fig. 1).
If the hood contains
any com-
bustible
materials
(i.e. a wood
covering),
it must
be a mini-
mum of 36" above the cooking
surface.
=
Consider Make-Up Air:
Due to the high volume of venti-
lation
air, a source
of outside
replacement
air
is
recom-
mended.
This is particularly
im-
portant
for tightly
sealed
and
insulated
homes.
A qualified
heating and ventilat-
ing contractor
should
be con-
sulted.
30" RANGE
36" RANGE
48" RANGE
PH30CS,
PHE30,36
PH36CS, 42CS
PHE36,42
HNW36YS
HNW42 YS
VTR 1O00Q,
VTR 1400Q
OR VTN 1030C
VTRIOOOQ, VTR1400Q
or VTN 1030C
VTRIOOOQ, VTR1400Q
VTRIOOOQ, VTR1400Q
PH48CS
VTR1000Q
PHE48,60
VTR1400Q
or VTN 1030C
HTN 142YS
HNI42YS
HTNI42YS
HNI42YS
HTNI48YS
HNI48YS
HTNI54YS
HNI54YS
VTR 1O00Q,
VTR1400Q
VTR 1000Q
VTR 1400Q
VTR1400Q
Notes: * For wall installations
where adequate
space is available,
the installer or user may elect to
use a hood that is wider than the range cooking
surface.
This may be particularly
beneficial
for those cases, such as a long duct run or heavy usage of the grill, in which improved
capturing
of the cooking
exhaust
is desired.
** Thermador
offers a choice of remote (VTRIOOOQ
or VTR1400Q)
or in-hood
(VTNI030C)
blowers
for use in wall installations.