Step 6: Electrical Requirements, Connection & Grounding
Prior to servicing
appliance,
always
disconnect
appliance
electrical
supply cord, if so equipped,
from wall receptacle.
If appliance
is hard-wired
to
power supply, disconnect
power to unit by turning
off the proper circuit breaker or disconnecting
the
proper fuse.
Dual Fuel range models
PD 304, PD36 and PD48
can be connected
or hard-wired
to the power supply
as described
on Page 15.
Chart
MODEL
PD304
PD36
PD48
C:
Electrical
NUMBERVOLTAGE
120/240 VAC
120/240 VAC
120/240 VAC
Supply
Circuit
Requirements
CIRCUIT
RATING
FREQUENCY
PHASE
35 Amps
60 Hz.
Single
35 Amps
60 Hz.
Single
50 Amps
60 Hz.
Single
For the PD Dual Fuel Ranges,
a neutral
supply
wire must
be provided
from the power
source
(breaker/fuse
panel) because critical range com-
ponents,
including
the
surface
burner
spark
reignition
module,
require
120 VAC to operate
safely and properly.
An improper
120/240
VAC
power
supply
will cause
malfunction,
damage
this appliance,
and possibly create a condition
of
shock hazard.
If the correct
power supply circuit
is not provided,
it is the responsibility
and obliga-
tion of the installer and user to have proper power
supply connected.
This must be accomplished
in
accordance
with all applicable
local codes
and
ordinances
by a qualified
electrician.
In the ab-
sence of local codes and ordinances,
the power
supply
connection
shall
be in accordance
with
the National
Electric Code.
Observe
all governing
codes
and ordinances
when grounding.
In the absence
of these codes
or ordinances
observe
National
Electrical
Code
ANSI/NFPA
No. 70 current issue. See Pages 15
and 16 for grounding
method.
Electrical
wiring diagrams
and schematics
have
been placed
in the toe kick area of the range for
access
by a qualified
service
technician.
The PD Dual Fuel Ranges may be connected
to
a 120/208
VAC power supply.
CAUTION
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig
(3.5 kPa.).
The appliance
and its individual
shut off valve must be disconnected
from the gas supply piping system
during any pressure testing of the system at test pressures
in excess of 1/2 psig (3.5 kPa.).
When checking the manifold gas pressure, the inlet pressure to the regulator should be at least 6" W.C.
(14.9 mb) for natural gas or 11" W.C. (27.4 mb) for propane.
Do not attempt any adjustment
of the pressure
regulator.