General requirements
Details on flushing procedure are given in the sec-
tion 7.4 of this manual.
Domestic hot water circuit (scale protection)
In areas where the water is 'hard' (i.e. more than
200 ppm total hardness as defined by BS 7593:
1993 Table 2) it is recommended that a proprietary
scale--- reducing device is fitted into the boiler cold
supply, within the requirements of the local water
company.
5.11

Electrical supply

Warning, this appliance must be earthed.
External wiring to the appliance must be carried
out by a competent person and be in accordance
with the current I.E.E. Regulations and any local
regulations which apply.
The boiler is supplied for connection to a 230 V~
50 Hz supply. The supply must be fused at 3A.
The method of connection to the electricity supply
must facilitate complete electrical isolation of the
appliance by the use of a fused double pole isola-
tor having a contact separation of at least 3 mm
between poles or alternatively, by the use of a 3A
fused three pin plug and unswitched shuttered
socket outlet both complying with BS 1363.
The point of connection to the electricity supply
must be readily accessible and adjacent to the
appliance except were the appliance is installed in
a bathroom this must then be sited outside the
bathroom.
rev. 17.09.93
23