Download Print this page

Inglis IGS326RD0 Installation Instructions Manual page 12

30" (76.2 cm) freestanding gas ranges

Advertisement

GASCONVERSIONS
Explosion
Hazard
Use a new AGA or CSA approved
gas supply
line.
Securely
tighten all gas connections.
if connected
to LP, have a qualified
person make sure
gas pressure
does not exceed 14" (36 cm) water
co[umm
Examples
of a qualified
person include:
licensed
heating
personnel,
authorized
gas company
personnel,
and
authorized
service
personnel
Failure to do so can result in death, explosion,
or fire.
L,! Ci!ii: !il
Tip Over Hazard
A child or adult can tip the range and be kilied.
Connect anti4ip
bracket to rear range foot.
Reconnect
the anti4ip
bracket,
if the range is moved.
Failure to follow
these instructions
can result in death
or serious
burns to children
and adults.
To Convert
Gas Pressure
Regulator
i
1. Ensure that the manual shutoff valve is in the dosed position
and the power supply cord is unplugged.
Remove storage drawer or warming drawer. Locate gas
pressure regulator at rear of storage or warming drawer
compartment.
NOTE: On models with a warming drawer, an access cover
must be removed from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulatoK
Gas pressure
regulator
3, Remove plastic cover from gas pressure regulator cap.
4, Turn gas pressure regulator cap (marked "N" on front of gas
pressure regulator) counterclockwise
with a wrench to
remove.
NOTE: Do not remove the spring beneath the cap.
B
Side
view
before
D
E
Side
view
after
c
A. Plastic cover
B. Gaspressur9 regulator cap with sofid end facing out
C. Gaspressure regulator cap with hoflow end facing out
D. Washer
E. Gaspressure regulator cap
5, Turn the gas pressure regulator cap over and reinstall on
regulator so that the hollow end faces out and letters "LP" are
visible.
6, Replace piastic cover over gas pressure regulator cap.
A
C
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
12

Advertisement

loading