Power Supply Specifications - HP ProLiant DL385 G6 User Manual

Hide thumbs Also See for ProLiant DL385 G6:
Table of Contents

Advertisement

BTUs per hour
Power supply output
Rated steady-state power
Rated peak power
*The system input requirements are based on measurements using hardware available at the publication
of this document. For updated information, see the HP website
efficient).

Power supply specifications

The following specifications provide information on the parameters of the power supplies as they were
designed. For more information on configuring power for a specific server, see the HP website
(http://www.hp.com/go/proliant-energy-efficient).
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 460 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Rated peak power
2285 at 100V to 120V AC
input
2217 at 200V to 240V AC
input
For more information, see
"Power supply specifications (on
page 89)."
For more information, see
"Power supply specifications (on
page 89)."
Value
100V to 120V AC
200V to 240V AC
50Hz to 60Hz
5.5A at 100V AC
2.6A at 200V AC
526 W at 100V AC input
505 W at 200V AC input
1794 at 100V AC input
1725 at 200V AC input
460 W at 100V to 120V AC
input
460 W at 200V to 240V AC
input
460 W at 100V to 120V AC
input
460 W at 200V to 240V AC
input
(http://www.hp.com/go/proliant-energy-
Specifications 89

Advertisement

Table of Contents
loading

Table of Contents