9
Use the included torx wrench to remove the stock regulator (see Figure 14). The old regulator may
be discarded.
10 The stepper motor (adjustable regulator) has an installation sheet included with it – make sure to
follow all of the directions. Place the stepper motor on the gas control valve (see Figure 15) – MAKE
SURE IT IS CORRECTLY ORIENTED. Secure using the screws included with the motor (see Figure
16) – tighten to 25 Lb-inches. Leak test this area after installation to verify proper installation.
11 Place the GreenSmart wiring harness in front of the stove, noting the position of each connector (see
.Figure 17).
© Travis Industries
(for qualified installers only)
Figure 15
4091120
Figure 14
Figure 16
Figure 17