Lopi Northfield GS Owner's Manual page 53

Direct vent freestanding stove
Table of Contents

Advertisement

Optional Equipment
6
Disconnect the comfort control valve connection (see Figure 8). Disconnect the burner control
connector from the fireplace burner control (see Figure 9).
7
Disconnect the on/off switch wires (labeled ON/OFF - see Figure 10). Unscrew the on/off/battery
plate from the control panel (see Figure 11).
8
Pull the plate and wiring forward (see Figure 12). Un-hook the wires from the wire-locks and remove
the wiring harness, plate, battery holder, and ac adapter (see Figure 13). These items may be
discarded.
© Travis Industries
(for qualified installers only)
Figure 8
Figure 10
Figure 12
4091120
53
Figure 9
Figure 11
Figure 13
100-01239_000