1 1

Listing and Code Approvals

A. Appliance Certifi cation
MODELS: SL-550TR-E, SL-750TR-E, SL-950TR-E
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88a-2007 • CSA 2.33a-2007
This product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for Use
at High Altitudes".
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured with
tempered glass may be installed in hazardous locations
such as bathtub enclosures as defi ned by the Consumer
Product Safety Commission (CPSC). The tempered glass
has been tested and certifi ed to the requirements of ANSI
Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certifi cation
Council SGCC# 1595 and 1597. Architectural Testing, Inc.
Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR
Section 1201.5 "Certifi cation and labeling requirements"
which refers to 15 U.S. Code (USC) 2063 stating "...Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered."
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
4
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. K • 9/08
C. BTU Specifi cations
Models
U.S. (0-2000 ft.) or
Canada (2000-4500 ft.)
U.S.
SL-550TR-E (NG)
SL-550TR-IPI-E (NG)
Canada
U.S.
SL-550TRLP-E (LP)
SL-550TRLP-IPIE (LP)
Canada
U.S.
SL-750TR-E (NG)
SL-750TR-IPI-E (NG)
Canada
U.S.
SL-750TRLP-E (LP)
SL-750TRLP-IPIE (LP)
Canada
U.S.
SL-950TR-E (NG)
SL-950TR-IPI-E (NG)
Canada
U.S.
SL-950TR-E (LP)
SL-950TR-IPI-E (LP)
Canada
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner orifi ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above
a 2000 foot elevation in the U.S.A., or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating
value of the gas has been reduced, these rules do not
apply. To identify the proper orifi ce size, check with the
local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Maximum
Minimum
Orifi ce
Input
Input
Size
BTU/h
BTU/h
(DMS)
21,000
15,000
#44
18,900
13,500
#45
20,600
14,600
#55
18,540
13,140
#56
24,300
16,900
#42
21,870
15,210
#43
23,400
17,600
#54
21,060
15,840
#55
30,400
20,900
#37
27,360
18,810
#38
30,800
23,000
#52
27,720
20,700
#53