Lamp Dousing

Fixture
Maintenance

Lamp Settings

Legend™ 1200E Spot User Manual
Due to the extreme heat produced by the lamp, closing the shutters/dimmers for an
extended period will cause a build-up of heat. However, a function in the fixture will
automatically reduce the power to the lamp when the shutters/dimmers are closed.
This will reduce the heat, and prolong the life of the fixture.
There is a time delay for which this feature will activate. Please see the set of
instructions below for further explanation.
1. Press <MENU>.
2. Select: Lamp Settings>Low Power Delay.
3. Rotating the <JOG WHEEL>, select 0~255s. This is the actual time delay.
4. Press <ENTER>.
This fixture has a user-selectable period for routine maintenance. This setting will
cause an error alert icon to appear on the home screen. Please see the set of
instructions below for further explanation.
1. Press <MENU>.
2. Select: Special Function>Fixture Maintenance>Interval.
3. Rotating the <JOG WHEEL>, select the actual time delay.
4. Press <ENTER>.
You may modify several parameters for the lamp's on/off state as well as the lamp
cooling. Please see the set of instructions below for further explanation.
Select: Lamp Settings>On/Off
Manually control the current state of the lamp.
Select: Lamp Settings>State Power On
When activated, the lamp will strike immediately upon the fixture receiving
power, provided that there is no ignition delay applied.
Select: Lamp Settings>Off via DMX
Allows remote Lamp Off through DMX.
Select: Lamp Settings>On if DMX On
When activated, the fixture will attempt to strike the lamp when DMX is
received by the fixture.
Select: Lamp Settings> Off if DMX Off
When activated, the fixture will attempt to turn off the lamp when DMX is
lost by the fixture.
Select: Lamp Settings> Cooling Mode> High
Manually set fans to maximum cooling level.
Select: Lamp Settings> Cooling Mode> Auto
Manually set fans to automatic cooling.
Select: Lamp Settings> Ignition Delay
This will cause an ignition delay upon power up the fixture, if the State
Power On option is activated.