Venting Fireplace - Top - Empire Comfort Systems DVCD32FP30N-1 Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVCD32FP30N-1:
Table of Contents

Advertisement

VENTING FIREpLACE - TOp (continued)
HARD ELBOW DIMENSIONS
FIREpLACE
SERIES
"A"
41-1/2"
DVCD32FP
(1054 mm)
41-1/2"
DVCD36FP
(1054 mm)
43-1/2"
DVCD42FP
(1105 mm)
FLEX pIpE 90 DEGREE BEND
FIREpLACE
SERIES
"A"
43"
DVCD32FP
(1092 mm)
43"
DVCD36FP
(1092 mm)
45"
DVCD42FP
(1143 mm)
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW OFF TOp OF FIREpLACE
SEE FIGURE 21 ON pAGE 18 FOR pERMISSIBLE "H" AND "V"
DIMENSIONS.
positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Page 20
D
C
B
V
H
C
B
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
"B"
"C"
4"
6"
(102 mm)
(152 mm)
(232 mm)
4"
6"
(102 mm)
(152 mm)
(232 mm)
4"
6"
(102 mm)
(152 mm)
(232 mm)
"B"
"C"
4-1/2"
6-1/2"
(114 mm)
(165 mm)
(232 mm)
4-1/2"
6-1/2"
(114 mm)
(165 mm)
(232 mm)
4-1/2"
6-1/2"
(114 mm)
(165 mm)
(232 mm)
Figure 25
Cutting the Hole (Figures 25)
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 10" (254mm) high x 10" (254mm) wide with its center line
determined by the amount of vertical rise and horizontal run of the
termination. (See Figure 25) When locating the hole it must be noted
that the bottom of the cap must be 12" (305mm) above the ground
level, and top of the cap must be no less than 18" (457mm) below a
combustible projection, and no closer than 9" (229mm) to any wall
running parallel to vent termination. (See Figure 26)
"D"
9 1/8"
9 1/8"
9 1/8"
"D"
9 1/8"
9 1/8"
9 1/8"
MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW
Figure 26
MAXIMUM HORIZONTAL
RUN WITH NO VERTICAL
RISE AND 90° ELBOW
Figure 27
minimum
28365-2-0811

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents