Triggercontrol - Toshiba BU406M Instruction Manual

Bu series cmos camera
Hide thumbs Also See for BU406M:
Table of Contents

Advertisement

TriggerControl

This section describes trigger control of TriggerControl category.
This camera provides two kinds of exposure synchronization.
1. Normal Shutter mode
2. Random Trigger Shutter mode
In Random Trigger Shutter mode, two kinds of trigger input are available.
1. Trigger signal via the I/O connector (HardwareTrigger)
2. Trigger command via the USB interface (SoftwareTrigger)
The following table shows the combination of operation mode.
Trigger Mode
Normal Shutter mode
Random Trigger Shutter mode
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
: Free run operation (internal synchronization)
: Synchronized with external trigger input
Table. Operation Mode
Synchronization
Free run
HardwareTrigger
SoftwareTrigger
* The camera operation not mentioned above is not guaranteed.
42 / 65
Exposure Control
"ExposureTime" register control
-Edge mode:TriggerSequence0
-Bulk mode:TriggerSequence6
"ExposureTime" register control
-Level mode:TriggerSequence1
Trigger pulse width control
-Edge mode:TriggerSequence0
-Bulk mode:TriggerSequence6
"ExposureTime" register control
D4223121B