FujiFilm FinePix A201 Service Manual page 2

U/e/eg-model
Hide thumbs Also See for FinePix A201:
Table of Contents

Advertisement

SAFETY CHECK-OUT
1. Check the area of your repair for unsoldered or
poorly soldered connections. Check the entire
board surface for solder splasher and bridges.
2. Check the interboard wiring to ensure that no
wires are "pinched" or contact high-wattage
resistors.
3. Look for unauthorized replacement parts, particu-
larly transistors, that were installed during a
previous repair. Point them out to the customer
and recommend their replacement.
4. Look for parts which, though functioning, show
obvious signs of deterioration. Point them out to
the customer and recommend their replacement.
2
After correcting the original problem, perform the following
safety check before return the product to the costomer.
FinePix A201 (U/E/EG) SREVICE GUIDE
5.
Caution:
For continued protection against
fire hazard, replace only with same
RISK OF FIRE-
type 2.5 amperes 125/250 volts
2.5A 125/250V
REPLACE FUSE
fuse.
AS MARKED
2.5A 125/250V
Attention:
Afin d'assurer une protection
permanente contre les risques
d'incendie, remplacer uniquement
par un fusible de meme, type 2.5
amperes, 125/250 volts.
6.
Warning:
To reduce the electric shock, be
WARNING!
careful to touch the parts.
HIGH VOLTAGE

Advertisement