Installer Final Check - Jenn-Air 720-0099-NG Instructions Manual

Stainless steel gas grill
Table of Contents

Advertisement

Adjustment Bolt

INSTALLER FINAL CHECK

1. Specified clearance maintained 24in. from
combustible materials/construction.
2. All internal packaging has been removed.
3. The hose and regulator are properly
connected.
WARNING
1. The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressure in excess of ½psi
(3.5kpa).
2. 2. The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas supply piping system at test
pressure equal to or less ½psi (3.5kpa)
Locking Nut
WARNING
Burner adjustments should only be performed
after the burners have cooled.
Always tighten the locking nut before relighting
If the flames have yellow tips, loosen the locking
the burner.
nut and move the bolt in a clockwise direction.
If the flames are making excessive noise or lifting,
loosen the locking nut and turn the bolt in a counter-
clockwise direction.
Remember to tighten the locking nut before
relighting the burner. If you have any questions
regarding flame stability, please contact customer
service at 1-800-554-5799.
4. The unit has been tested and is free of leaks.
5. The gas supply shut off valve has been
located.
6. All burners are factory installed.