Rotisserie Troubleshooting - Weber Summit Gold D LP Owner's Manual

Owner manual
Table of Contents

Advertisement

Problem
Burner does not light.
Burner does not light or burner
has a small flickering flame.
If problems cannot be corrected by using these methods, please contact the Customer
Service Representative in your region using the contact information sheet provided with
your manual.

Rotisserie Troubleshooting

Check
Did you hold the burner control
knob down and hold down for 20
seconds until after burner ignited?
Is the igniter sparking?
The excess flow safety device,
which is part of the grill to cylinder
connection, may have activated.
Cure
Try to relight burner by holding
burner control knob down and
continue holding down until 20
seconds after burner has ignited.
Replace battery in igniter button
module.
Reseat burner ring.
Too reset the excess flow safety
device turn all burner control knobs
and the cylinder valve OFF.
Disconnect the regulator from the
cylinder. Turn burner control knobs
to HIGH. Wait at least 1 minute. Turn
burner control knobs OFF.
Reconnect the regulator to the
cylinder. Turn cylinder valve on
slowly. Refer to "Lighting
Instructions"