GE JGBP26GEN Use And Care & Installation Manual page 39

Self-cleaning gas range
Table of Contents

Advertisement

Install a manual gas line shut-off valve in the
1.
gas line in an easily accessed location outside of
the range. Make sure everyone operating the
range knows where and how to shutoff the gas
supply to the range.
2. Install male 1/2" flare union adapter to the
1/2" NPT internal thread elbow at inlet of
regulator.
On models equipped titi dual
install the male pipe thread end of
burners,
the 1/2" flare union adapter to the 1/2" N~
internal thread at inletof pressure regulator.
Use a backup wrench on the regulator fitting
to avoid damage.
remove the 90° elbow for easier installation.
3. Install male 1/2" or 3/4" flare union adapter
to the NPT internal thread of the manual shut-
off valve, taking care to back-up the shut-off
valve to keep it from turning.
Connect flexible metal appliance connector
4.
to the adapter on the range. Position range
to permit connection at the shut-off valve.
5. men all connections have been made, make
sure all range controls are in the off position and
turn on the main gas supply valve. Use a liquid
leak detector at all joints and connections to
check for leaks in the system.
CHECK FOR GAS ~.
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. men
using test pressures of 1/2 psig or less to test the
gas supply system, simply isolate the range from
the gas supply system by closing the individual
shut-off valve.
ELECTRIUL
COnneCtiOnS
Electrical
Requirements
circuit protected by a 15-amp or 2@amp circuit
breaker or time delay fuse.
Extension Cord Cautions
Because of potential safety hazards associated
with certain conditions, we strongly recommend
against the use of an extension cord. However,
if you still elect to use an extension cord, it is
absolutely necessary that it be a UL-listed,
3-wire grounding-type appliance extension cord
and that the current carrying rating of the cord
in amperes be equivalent to, or greater than,
the branch circuit rating.
Grounding
FOR PERSONW SN~, THIS NPLWCE
The power cord of this appliance is equipped
with a three-prong @rounding) plug which
mates with a standard three-prong grounding
PREFERRED
'
METHOD
ENSURE PROPER
GROUND EXISTS
BEFORE USE
qualified electrician to make sure the receptacle
is properly grounded.
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded threeprong wall receptacle.
DO NOT, UNDER ANY CIRCUM~ANCES,
CUT OR REMO~ THE THIRD (GROUND)
PRONG ~OM THE POWR CORD.
wall receptacle
to minimize the
possibility of
electric shock
hazard from
this appliance.
should have the
wall receptacle
and circuit
checked by a
(continued next page)
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents