Technical Specifications - CyberPower OL1000RTXL2U User Manual

Hide thumbs Also See for OL1000RTXL2U:
Table of Contents

Advertisement

Model
Configuration
Capacity (VA)
Capacity (Watts)
Form Factor
Energy-saving Technology
Input
Input Voltage Range
Input Frequency Range
Input Power Factor
Cold Start
Output
Output Waveform
Output Voltage*
Output Frequency
Transfer Time (Typically)
Rated Power Factor
Harmonic Distortion
Crest Factor
ECO Mode Voltage Regulation
UPS Outlets
Protection
Surge Protection
Phone / Network Protection
Overload Protection
Short Circuit Protection
Battery
Specifications
Recharge Time (Typically)
Sealed, Maintenance Free
Hot-Swappable
Status Indicators
LCD Screen
LED Indicators
Audible Alarms
Environment
Operating Temperature
Operating Relative Humidity
Management
On-Device Features
Connectivity Ports
SNMP/HTTP Capable
Software
Power Management Software
Physical
Dimensions
Net Weight
Safety
Conformance Approvals
*)100V are derated by 20%, 110 V are derated by 10%
Copyright © 2012 CyberPower Systems, Inc.

TECHNICAL SPECIFICATIONS

OL1000RTXL2U
OL1500RTXL2U
1000VA
900W
100, 110, 115, 120, 125Vac (Configurable) ±2%
50 / 60Hz (Auto-Sensing or Configurable) ±0.25Hz
0.9
THD < 3% at Linear Load, < 5% at Non-linear Load
(8) NEMA 5-15R
Line Mode:
105~125% Load for 1 min,
Battery Mode: 105~130% Load for 10 sec,
UPS Output Cut off Immediately or Input Fuse / Circuit Breaker Protection
(3) 12V/9AH
Multi-Function LCD Readout that Supports:
Multi-Language Interface,
(22) Types of Function Setting,
Power On (White),
Bypass Mode (Yellow), Fault (Red),
Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery
Self Test, Auto-Charge, Auto-Restart, Auto-Overload Recovery
(1) Serial Port (RS232), (1) USB Port, (1) Relay Out
(1) Expansion Port (With optional SNMP card)
L x W x H = 16.9 x 17 x 3.5in.
(43 x 43.3 x 8.8cm)
39.6lbs(18Kg)
14
OL2200RTXL2U
1500VA
2200VA
1350W
1800W
Rackmount / Tower
Yes, ECO Mode Efficiency > 93%
100~125Vac
50 / 60Hz
0.99
Yes
Sine wave
0ms
3 : 1
±10%, ±15% (Configurable)
(6) NEMA 5-20R,
(1) L5-20R
IEC 61000-4-5 Level 3
RJ11/RJ45 (One In/One Out)
126~150% Load for 10 sec
131~150% Load for 2 sec
4 hours
Yes
Yes
(19) Types of Read Out,
(3) Event Logs
Line Mode (Green),
32℉ to 104℉ ( 0℃ to 40℃)
0 to 90% Non-Condensing
®
PowerPanel
Business Edition
L x W x H = 23.6 x 17 x 3.5in.
CE, UL
OL3000RTXL2U
3000VA
2700W
0.82
0.9
(6) NEMA 5-20R,
(1) L5-30R
(6) 12V/9AH
Battery Mode (Yellow),
Replace Battery (Red)
(60 x 43.3 x 8.8cm)
68.2lbs(31Kg)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents