User's Manual
CyberPower Systems (USA), Inc.
4241 12th Avenue East Suite 400 Shakopee, MN 55379
Phone: 877-297-6937
Fax: 952-403-0009
www.CPSww.com
OL6000RT3UTAA
OL8000RT3UTAA
OL10000RT3UTAA

Advertisement

Table of Contents
loading

Summary of Contents for CyberPower OL6000RT3UTAA

  • Page 1 User’s Manual OL6000RT3UTAA OL8000RT3UTAA OL10000RT3UTAA CyberPower Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Phone: 877-297-6937 Fax: 952-403-0009 www.CPSww.com...
  • Page 2: Important Safety Instructions

    REQUIRED PRECAUTIONS. KEEP UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES! CAUTION! Do not use an improper size power cord as it may cause damage to your equipment and cause fire hazards. Copyright © 2011 CyberPower Systems, Inc.
  • Page 3 Rackmount right rail * 2 sets Plastic washers (8) * 2 sets Phone line Screw hole dust covers (10) * 2 sets USB communication cable Power cords PowerPanel® Business Edition software CD Serial Interface Cable (RS-232) Copyright © 2011 CyberPower Systems, Inc.
  • Page 4: Hardware Installation

    Step 5: Place the internal battery trays back into the Battery module (See page 17) Once completed, perform the same steps for the Power module. CAUTION! The Battery module must be installed below the Power module. Copyright © 2011 CyberPower Systems, Inc.
  • Page 5: Vertical/Tower Installation

    CAUTION! Do not work alone under hazardous conditions. CAUTION! In case of the risk of electric shock, do not remove the top cover. CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected. Copyright © 2011 CyberPower Systems, Inc.
  • Page 6: Installing Your Ups System

    UPS will continuously emit two beeps per second. For resetting the unit, unplug some equipment from the outlets. Make sure your equipment carries a load current within the unit’s safe range, (refer to the technical specifications). Copyright © 2011 CyberPower Systems, Inc.
  • Page 7: Hardwiring The Input/ Output Terminals

    Step 2: Fix the bottom cover on the terminal block Loosen the four screws to separate the top and bottom covers. Tighten the two screws to fix the bottom cover on the terminal block. Copyright © 2011 CyberPower Systems, Inc.
  • Page 8 Connect the three wires to the output terminal block. Connect the three wires to the input terminal block. Step 5: Fix the top cover on the bottom cover Tighten the six screws to fix the top cover on the bottom cover. Copyright © 2011 CyberPower Systems, Inc.
  • Page 9: Backfeed Protection

    3. Hardwire the input terminals and “Backfeed Protection Connector” as shown in the following diagram. 4. The external isolation device must be installed in the Mains path. Mains L1 L2 PE IP-L1 IP-L2 PSDR 2A Fuse Backfeed (Slow Blow) AC-L1 AC-L2 Copyright © 2011 CyberPower Systems, Inc.
  • Page 10: Basic Operation

    It is recommended to install the PowerPanel® Business 15. Extended Runtime Battery Module Connector Edition Agent software on the PC/Server connected with Connection for additional CyberPower XL Battery modules. the USB cord. 16. EPO (Emergency Power Off) Connector 11. Remote Control Port Enables an emergency UPS Power-Off from a remote location.
  • Page 11 Step 5: Use a power cord to plug AC input inlet of the battery module into a wall receptacle. Step 6: Turn on the DC breaker of the Battery module. Copyright © 2011 CyberPower Systems, Inc.
  • Page 12 Step 6: Use a power cord to plug AC input inlet of the 2 battery module into AC output outlet of the 1 Battery module. Step 7: Turn on the DC breaker of the 2 Battery module. Copyright © 2011 CyberPower Systems, Inc.
  • Page 13: Led Indicators - Ups Status

    Press this button to scroll up in the LCD menu. ▼ Press this button to scroll down in the LCD menu. ENTER Press this button to select an option. Press this button to cancel or return to previous LCD menu. Copyright © 2011 CyberPower Systems, Inc.
  • Page 14: Lcd Setup Functions

    Date & Time Displays the present Date & Time - - - - / - - / - - - -:- - Next BAT Change Displays the next Battery Change Date & Time XXX / XXXX Copyright © 2011 CyberPower Systems, Inc.
  • Page 15: Lcd Event Log

    You may be prompted to save the selection, if so press the “ENTER” button to save the setting. Some options are saved and started automatically. (See the following table for additional details.) Press the “ESC” button to cancel or return to the previous LCD menu. Copyright © 2011 CyberPower Systems, Inc.
  • Page 16 [Disable] [Enable] Disable *) 200V are derated by 20%, 208 V are derated by 10% for OL6000RT3UTAA **) This function can’t be set when Manual Bypass, Generator Mode or Converter Mode is enabled. ***) UPS has no bypass when Generator Mode is enabled.
  • Page 17: Lcd Module Remote Control And Wall-Mounting Instructions

    Step 4: Mount LCD Module on the Wall SAFETY PRECAUTIONS CAUTION! It must be done by qualified personnel. CAUTION! To avoid electric shock, turn off and unplug the unit before installing REMOTE CONTROL or WALL-MOUNTING INSTRUCTIONS. Copyright © 2011 CyberPower Systems, Inc.
  • Page 18: Maintenance

    Only use replacement batteries which are certified by proper disposal and recycling of batteries. Do not dispose of batteries CyberPower Systems. Use of incorrect battery type is an electrical in fire. hazard that could lead to explosion, fire, electric shock, or short circuit.
  • Page 19: Technical Specifications

    L x W x H = 26 x 17 x 5.2in. (66 x 43.3 x 13.2cm) Net Weight--Power Module 53lbs(24Kg) Net Weight--Battery Module 167.2lbs(76Kg) 171.6lbs(78Kg) Safety Conformance Approvals CE, UL *)200V are derated by 20%, 208 V are derated by 10% for OL6000RT3UTAA Copyright © 2011 CyberPower Systems, Inc.
  • Page 20: Troubleshooting

    Internal DC bus voltage is too high or too low. CyberPower Systems Inc. www.cpsww.com © Entire contents copyright 2011 CyberPower Systems Inc., All rights reserved. Reproduction in whole or in part ® ® without permission is prohibited. PowerPanel Business Edition and PowerPanel Personal Edition are trademarks of CyberPower Systems Inc.
  • Page 21: Product Registration

    If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).
  • Page 22 (collectively, "High Risk Activities"). CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums. CyberPower does not authorize use of any Product in any High Risk Activities or with Aquariums.
  • Page 23: Conformance Approvals

    Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada. This document is believed to be accurate, but CyberPower reserves the right to change or correct the contents and does not assume any responsibility for omissions or errors.