HP NetServer AA 4000 Manual page 262

Hp netserver aa 6200 solution release 3.0 messages
Hide thumbs Also See for NetServer AA 4000:
Table of Contents

Advertisement

Chapter 13
IOPn.MtcMon status: ESIx is faulted and requires repair.
Variables
x – the ID of the Endurance System Interconnect (ESI) that is faulted
Severity
Error
Description
The ESI specified in the message has experienced one or more failures that prevent it from
being used in the Endurance server configuration. The ESI remains in the faulted state until
you resolve the situation.
Often an IOP or CE is also removed when this message occurs.
Related Messages
IOPn.MtcMon status: IOPx has been removed from service.
IOPn.MtcMon status: CEx has been removed from service.
Hardware/Software
This message is usually a result of a hardware failure.
Action
• Examine the event log for additional details about the reason for the failure.
• Repair and/or replace any faulty hardware as necessary.
• Once you resolve the condition, issue an ESI Enable Operation command. The Endurance
IOPn.MtcMon status: IL12 has been enabled by operator request.
Severity
Informational
Description
IL12 was enabled using the IL12 Enable command. IL12 was previously faulted and is now
available.
Related Messages
IOPn.MtcMon status: IL12 is FAULTED and requires repair.
Hardware/Software
This message is generated as a result of issuing a software command.
Action
No action is required.
252
server attempts to reconfigure as required.
MtcMon Messages

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netserver aa 6200

Table of Contents