Server Console Alert Messages (continued)
Alert Message
Event "Status Changed from Upper Critical to
Upper Noncritical" reported in the Voltage Probe
group.
Event "Status Changed to OK" reported in the
Temperature Probe group.
Event "Status Changed to Lower Critical"
reported in the Temperature Probe group.
Event "Status Changed to Upper Critical"
reported in the Temperature Probe group.
Event "Status Changed from OK to Lower
Noncritical" reported in the Temperature Probe
group.
Event "Status Changed from OK to Upper
Noncritical" reported in the Temperature Probe
group.
Event "Status Changed from Lower Critical to
Lower Noncritical" reported in the Temperature
Probe group.
Event "Status Changed from Upper Critical to
Upper Noncritical" reported in the Temperature
Probe group.
Event "Internal Error" reported in the Processor
group.
Event "Thermal Trip Error" reported in the
Processor group.
Event "FRB Error" reported in the Processor
group.
Event "Redundancy Lost" reported in the Power
Unit Global Table group.
Event "Redundancy Regained" reported in the
Power Unit Global Table group.
Event reported on the Storage Device Event
Type attribute in the Storage Device Events
group.
Event reported on the Storage Controller Event
Type attribute in the Storage Controller Events
group.
Event "Status Change to Ok" reported in the
System Slot group.
Event "Status Changed to Non-Critical" reported
in the System Slot group.
Event "Status Changed to Critical" reported in
the System Slot group.
Event "Slot Power On" reported in the System
Slot group.
Event "Slot Power Off" reported in the System
Slot group.
38
Description
A Voltage probe changed its status from Upper Critical
to Upper Noncritical state.
A Temperature probe changed its status to an OK state.
A Temperature probe changed its status to Lower
Critical state.
A Temperature probe changed its status to Upper
Critical state.
A Temperature probe changed its status from normal to
Lower Noncritical state.
A Temperature probe changed its status from normal to
Upper Noncritical state.
A Temperature probe changed its status from Lower
Critical to Lower Noncritical state.
A Temperature probe changed its status from Upper
Critical to Upper Noncritical state.
A system processor reported an internal error.
A system processor reported a Thermal Trip error.
A system processor reported an error during the FRB
(Fault Resilient Boot) sequence.
A power unit on the system lost the redundancy state.
A power unit on the system regained the redundancy
state.
A predictive failure noncritical on a SCSI device.
A SCSI controller reported a state change.
A PHP slot changed its status to OK.
A PHP slot changed its status to Non-Critical.
A PHP slot changed its status to Critical.
A PHP slot changed its power state from Off to On.
A PHP slot changed its power state from On to Off.