Intel Platform Instrumentation Control (PIC) Console User's Guide
NOTES
Event actions you have configured, the temperature display format, and
refresh rate are not affected by the Restore Factory Default option.
Default threshold values are stored in Sensor Data Records (SDR) in
nonvolatile storage on the motherboard. These values are determined and
configured during motherboard manufacturing and are therefore not
documented in this manual.
Indications may be generated if the restore of the default threshold value
crosses the current sensor value. For example:
User defined threshold limit 13.5 V
Current sensor value 13.0 V
Default threshold value 12.5 V
When you select the Restore Default Settings action, threshold restore may
cause a threshold crossing. In the above example, PIC would detect a
threshold crossing and generate an indication. The actions associated with
that indication would occur.
To avoid the possibility of unwanted indications when restoring defaults
settings, adjust the user-defined threshold value so the current sensor value is
not between the user-defined threshold value and the default threshold value.