(21) Addition of specified value to point variable P ................... Code 0115
The specified value is added to the point variable P.
QWn+22
IWm+22
(Details)
Addition value:
A value of 1 to 999 can be specified.
(Example)
Transmission example 1:
10 is added to the point variable P.
Response example 1:
It is normally ended.
Command option
QWn+20
QWn+18
Command response
IWm+20
IWm+18
QWn+22
QWn+20
QWn+18
0000
0000
0000
IWm+22
IWm+20
IWm+18
0000
0000
0000
87
CHAPTER2 PROFIBUS Unit
QWn+16
QWn+14
IWm+16
IWm+14
QWn+16
QWn+14
QWn+12
0000
0000
000A
IWm+16
IWm+14
IWm+12
0000
0000
0000
QWn+12
Addition value
IWm+12
QWn+10
QWn+8
0000
0115
IWm+10
IWm+8
0000
0200