Setup

Cresnet
Ethernet
Net ID
IP ID
®
12 • Isys
5.7" Wall Mount Touchpanel: TPS-6L

Network Wiring

®
When wiring the Cresnet
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION: Insufficient power can lead to unpredictable results or damage
to the equipment. Please use the Crestron Power Calculator to help calculate
how much power is needed for the system (www.crestron.com/calculators).
For larger networks, use a Cresnet Hub/Repeater (CNXHUB) to maintain signal
quality.
For more details, refer to "Check Network Wiring" on page 46.
The TPS-6L can also use high-speed Ethernet for communications between the
device and a control system, computer, digital media server and other IP-based
devices.
For information on connecting Ethernet devices in a Crestron system, refer to the
latest version of the Crestron e-Control
available for download from the Crestron website (www.crestron.com/manuals).

Identity Code

The Net ID of the TPS-6L has been factory set to 03. The Net IDs of multiple
TPS-6L devices in the same system must be unique. The Net ID is set using the
internal setup menu (refer to "Interface Menu" which starts on page 15). The Net ID
may also be set from a personal computer (PC) via the Crestron Toolbox™ (refer to
"Establishing Communication" on page 43).
When setting the Net ID, consider the following:
The Net ID of each unit must match an ID code specified in the SIMPL™
®
Windows
program.
Each network device must have a unique Net ID.
For more details, refer to the Crestron Toolbox help file.
The IP ID is set within the TPS-6L's table using Crestron Toolbox. For information
on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs of multiple
TPS-6L devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the SIMPL
Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.
or Ethernet network, consider the following:
Reference Guide (Doc. 6052), which is
Operations & Installation Guide - DOC. 6630A