6.0 Diagnostics Quick Reference Charts; Fault Display/Download Mode; Hardware Output Test Mode - Fisher & Paykel DishDrawer DD603 Service Manual

Dishdrawer
Hide thumbs Also See for DishDrawer DD603:
Table of Contents

Advertisement

March 2004

6.0 DIAGNOSTICS QUICK REFERENCE CHARTS

6.1

Fault Display/Download Mode:-

Press and hold Keylock, then Start/Pause for 5 seconds
All LEDs & LCD segments except Keylock are illuminated
Press Start / Pause
This initiates Pen upload via lower tub-home light pipe. At the same time the current and then the previous fault code
will be displayed in the LCD screen & on the secondary control panel LEDs. To read the fault code on the
secondary display refer to Section 7.1 on Fault Codes.
Press Keylock
This will clear current fault code. Note if you press Keylock again you will remove the previous fault
Press Power
To exit
6.2

Hardware Output Test Mode:-

Press and hold Keylock, then Start/Pause for 5 seconds
All LEDs & LCD segments except Keylock are illuminated
Press Power Button Once
HO will show in the display
Press Start/Pause
Scroll through the following outputs using Start/Pause. Turn the outputs on & off using Keylock button.
Press Power
To exit
Note: Scrubbing Brush = output on, No Scrubbing Brush = output off (on integrated models a green LED above the start/pause button is
used inplace of the scrubbing brush)
LCD
Norm
Fast
Display
LED
LED
-------------------------------------------------------------------------------------------
bL
Off
Off
Er
Off
Off
Ld
Off
Off
dd
Off
On
FU
Off
On
P1
Off
On
P2
Off
On
rd
On
Off
dF
On
Off
LE
On
Off
C1
On
Off
C2
On
On
°C
On
On
°E
On
On
Tub Home Sensor test:- keylock symbol on = tub closed, off = tub open
(integrated: Heavy, Normal, Fast, Delicate, Rinse LEDs showing)
Deli
Rinse
Hardware Output
LED
LED
Off
On
Backlight
On
Off
Element Relay
On
On
Lid Motors (will run for 10 seconds)
Off
Off
Detergent Diverter Valve
Off
On
Fill Water Valve
On
Off
Motor Wash direction (2300-2850 rpm)
On
On
Motor Drain direction (5000 rpm)
Off
Off
Rinse Aid Dispenser (dispenses current setting)
Off
On
Drying fan
On
Off
Rinse Aid LED
On
On
Water Softener Diverter Valve
Off
Off
Water Softener Brine Pump
Off
On
Displays current water temperature.
On
Off
Displays controller rail voltage
- 24 -