Number
Description
Menu item
125
Type of waiting position
0 = Feeding clamp runs to the waiting position
1 = Feeding clamp remains in stacking position
126
Material feed to the stacking position
127
Loading speed %
128
Return speed %
129
Downholder on / off
130
Sewing mode
0 = Constant sewing length
1 = Light-barrier for flap scanning
131
Light-barrier correction seam beginning 1/10 mm
132
Light-barrier correction seam end 1/10 mm
133
Material feed to the waiting position
134
Max. flap length
135
Flap clamp on / off
136
Pedal mode
0 = normal
1 = Pedal has to be in basic position before the
next step
2 = Pedal actuation for moving in sewing position
(flap clamp)
Minimum
Maximum
value
value
1
100
10
100
10
100
-20
20
-20
20
1
515
30
180
Standard
value
1
40
80
80
on
0
0
0
100
180
on
0
17