Schwinn 425 Elliptical Assembly Manual page 31

Assembly and owner's manual
Table of Contents

Advertisement

Console shuts off (enters
sleep mode) while in use
Fan (if equipped) will not
turn on or will not turn off
Unit rocks/does not sit
level
Resistance does not
change
Drive train click/tick noise
once per full crank revolu-
tion
Squeaking noise that
appears a few minutes into
a workout and normally will
get progressively worse as
the workout continues
Check data cable integrity
Check data cable
connections/orientation
Reset machine
Check magnet position
(requires shroud removal)
Check RPM Sensor
(requires shroud removal)
Check data cable integrity
Check data cable
connections/orientation
Reset machine
Check leveler adjustment
Check surface under unit
Check that unit powers up
Check crank/pulley
assembly
Check foot assemblies,
leg assemblies, handlebar
assemblies
Bolt that connects the
swing arms to the axle
running through the
console mast
All wires in the cable should be intact. If any are cut or
crimped, replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Magnet should be in place on pulley.
RPM sensor should be aligned with magnet and connected
to data cable. Re-align sensor if necessary, replace if any
damage to sensor or connecting wire.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Leveling feet may be turned in or out to level the machine.
Adjustment may not be able to compensate for extremely
uneven surfaces. Move the machine to level area.
If machine powers up and otherwise functions normally,
contact Customer Care for assistance.
Disconnect left and right foot assemblies and rotate crank.
If sound persists, replace crank/pulley assembly. If sound
does not come from rotating crank, check foot assemblies
and upper/lower handlebars.
Manually move foot, leg, and handlebar assemblies to isolate
sound. Replace part making sound.
Loosen pivot rod bolt slightly until noise goes away. See
video for demonstration. White lithium grease can also be
applied for a temporary fix. Contact Customer Care for as-
sistance.