Instant Arming

INSTANT ARMING allows exit/entry zones to immediately go into alarm when violated, with no Exit/Entry time delay. This
feature can be used to provide instant protection while you or someone else is on the premises. With the "Classic" keypads,
to arm "Stay" and obtain Instant Arming, press
ries" keypads, enter your user code and press
automatically reset on disarming.
Auto Arming (Not for UL Installations)
AUTO ARM allows the User to automatically arm the system at a specified time of the day and on specific days of the week.
Schedule a specific closing time on any/all day(s) of the week. After a specific Fail-to-Close Window Start Time, if the user
has not Armed the system during the Window Length, and the system has been instructed to "Fail-to-Close' and 'Auto Arm if
not closed at end of Window" then the system will arm, providing a 15 minute warning. CAUTION: If Automatic Interior By-
pass is selected, panel will Auto Arm in STAY Mode.
Delaying an Auto Arm (Not for UL Installations)
During the 15 minute pulsating sounder warning of an Auto Arm, a User can press the
DELAY AUTO ARM / PRESS 1-4 / N" is displayed. Enter the number of hours to delay arming, followed by the
ton. If "DELAY AUTO ARM Y/N" is displayed, press the "NEXT/YES" button. The sounder can be silenced by pressing the
button during the 15 minute interval, but will come back on in the last 1 minute. This feature may be canceled by arming and
disarming the keypad.
EZ Arm (Easy Arm)
EASY ARM provides one button arming for non-security critical premises. Select Easy Arming for each Keypad, with optional
reporting of Easy Arm Closings as User 35. Disarming still requires a valid user code.
U
!
To arm, press the
!
To arm, press and hold

Keyswitch Arming

KEYSWITCH ARMING allows a zone input to be used to arm/disarm. The area will arm/disarm when the zone is
momentarily shorted through a Momentary Switch. An end-of-line resistor must be used. Select Keyswitch Arm to
optionally report as User 36.
Maintained-Key Input Arming
KEYSWITCH ARMING with MAINTAINED-KEY INPUT ARMING is similar to Keyswitch arming, except the zone input
must remain shorted to be armed and remain open to be disarmed.
Remote Arming (Not for UL Installations)
REMOTE ARMING allows computer software control of arming/disarming of the system for non-security critical
installations. Select Remote Arm to optionally report as User 34.
Priority Arming
A 2-second tone and "CAN'T ARM SYSTEM/ZONE FAULTED" displayed when attempting to arm indicates a priority condition; that
is, a problem exists on at least one zone that has been designated as a Priority Zone, or a system trouble exists. The
trouble(s) must be corrected before the panel can be armed. The display will read "ZONE FAULTED", then automatically
scroll through all unsecured zones. If a system trouble is indicated, it will display the system trouble.
Area Arming/Manager's Mode
In a partitioned system, either or both secured areas may be armed (or disarmed) from the Manager's Mode (if enabled).
The Manager's Mode, is a low-security mode of operation. It provides quick access to other areas without having to go
to another keypad of another area.
To arm or disarm the alternate area (for "Classic" keypads):
L
NAPCO Security Systems
and
E
. Then press and hold
P
button for "Classic" keypads;
or
for 3 seconds for "K Series" keypads.
P
Q
, then enter your user code and press
F
until keypad beeps Instant Arming will be
P
X
GEM-P1632 Installation Instructions
Page 23
D
. With the "K Se-
or
button, until "TO
R
A
U
or
!
D
but-
C